 | |  | | | Resikom Integrity Testing LtdRoom Integrity Testing UK Pressure Testing UK Gas Suppression System Testing UK Fan Testing UK, Gas Suppression System Installation UK, Gas Suppression System Servicing UK | | | Company | Resikom Integrity Testing Ltd | | | Contact | Steven Page | | Address | 111 Delaware Crescent Shoeburyness Southend On Sea Essex London England UK SS3 9PJ (MAP)
| | Telephone | 0845 686 6066 | | Mobile | 07894 521 989 | | | Email | | | Website | www.roomintegritytesting.com | | | Welcome to Resikom Limited - Room Integrity Testing International Standard (BS:ISO14520) requires that an enclosure integrity test (aka room integrity test, fan test, or pressure test) be conducted on system installation and thereafter at annual intervals.
Our staff have been at the forefront of such testing for well over a decade both in the UK and Ireland, as well as elsewhere overseas.
The test was introduced as an environmentally friendly alternative to discharge testing following the phase out of halon extinguishant under the Montreal Protocol on ozone depletion. It is applicable to all sizes of enclosure and all extinguishing gases, including argonite, inergen, proinert, IG55, FM200, FE25, HFC 227ea, FE25, Novec 1230 and CO2.
The testing is clean and non-disruptive, using a door mounted fan(s) to measure leakage flow. Work may continue as normal in the room during the test. An immediate result is obtained for the total room leakage and consequent extinguishant retention time. If this is below that required by the Standard, a detailed inspection is carried out to identify all major leakages for remedial sealing. A formal report is issued detailing the results and any recommendations. This should be retained for regulatory authority/ insurers reference.
Requirements As from January 2001, gaseous fire extinguishing systems have been controlled by International Standard No 14520. This covers all the extinguishing gases introduced to supersede halon (e.g. argonite, inergen, FM200). It was published following the European Union decision requiring halon systems to be decommissioned by the end of 2003. Under this Standard, it is a requirement that an enclosure integrity test is conducted both upon system installation and annually thereafter as part of the routine maintenance schedule. This is to ensure that an extinguishing concentration is held for a sufficient time to prevent reignition in the event of a fire.
References :-
- BS:ISO 14520 Gaseous Fire Extinguishing Systems (2000)
- EU Regulation 2037/2000 (26/6/00)
- BFPSA Code of Practice for Gaseous Fire Fighting Systems
- LPC Recommendations for Loss Prevention in EDP Installations
- NFPA 2001 Clean Agent Fire Extinguishing Systems (2000)
Click here to read our FAQs
| | | Products and Services | | Resikom Integrity Testing Ltd is a SelfBuild supplier | | Fire Protection Services | | Gas Detection | | Gas Leak Detection Equipment | | Heating Contractors and Consultants | | Leak Detection | | Smoke alarms - Domestic and Commercial | | | Regions Serviced | | England - East Midlands | | England - Eastern | | Ireland | | England - London | | Northern Ireland | | England - South East | |
|
| | |  | | |
|
| |
| |
|
              
|
|
|
| Flagship Media Group LtdUnit C3, 6 Westbank Drive, Belfast, BT3 9LA, Northern Ireland Tel (+44) 28 9031 9008 Contact : Click here |
keycons003 / keycons003xLIS / keycons003x21 19/05/2013 05:59:08 / A7 / B8 / 0.03125, 23.20.196.179 / BOT1
Room Integrity Testing UK Pressure Testing UK Gas Suppression System Testing UK Fan Testing UK, Gas Suppression System Installation UK, Gas Suppression System Servicing UK
Room Integrity Testing UK Pressure Testing UK Gas Suppression System Testing UK Fan Testing UK, Gas Suppression System Installation UK, Gas Suppression System Servicing UK
Get the FREE Build App for iPhone / iPad
Test
|